-
COD ID BLACK UV — Reagent-Free Online COD Monitor | UV254 Probe $11,000.00
$11,000.00×

Suspended Solids / Turbidity Probe with Self-Cleaning Wiper
Self-cleaning turbidity and suspended solids probe by InstroDirect for continuous measurement of MLSS, TSS, and activated sludge concentration in WWTPs and industrial process water. Integrated mechanical wiper clears the optical window on a timed cycle, eliminating drift from biofilm and particulates. 316 stainless body, RS485 Modbus RTU, and Pt1000 temperature compensation. Backed by AU technical support and on-site calibration.
- Estimated delivery time 3-30 days - some items in stock in Australia
- 12 months standard warranty
- Genuine manufacturer-made products
Product details
Self-Cleaning Suspended Solids & Turbidity Probe — Wiper Equipped
The InstroDirect IDTB-SS-W Suspended Solids / Turbidity Probe with Self-Cleaning Wiper is a heavy-duty suspended solids and turbidity probe designed for activated sludge and process water where a non-wiping optical sensor would foul within hours. A mechanical wiper sweeps the optical window on a user-configurable cycle (typically every 15 minutes), so the probe delivers drift-free readings in MLSS up to 30 g/L without daily manual cleaning.
Technical Specifications
| Parameter | Specification |
|---|---|
| Measurement methods | Dual: ISO 7027 (turbidity) + 90° scattered infrared (suspended solids) |
| Turbidity range | 0 – 4000 NTU |
| Suspended solids range | 0 – 30 g/L (0 – 30,000 mg/L) |
| Accuracy | ±5% of reading (SS) / ±2% of reading (turbidity) |
| Resolution | 0.1 mg/L (SS low range), 0.01 NTU (turbidity) |
| Wiper cycle | User-configurable 1 min – 24 hr; typical 15 min |
| Temperature range | 0 – 50 °C |
| Operating pressure | ≤ 4 bar |
| Output signal | RS485 Modbus RTU |
| Power supply | 12 – 24 VDC, < 2 W (during wipe) |
| Body material | 316 stainless steel, sapphire optical windows, POM wiper arm |
| Process connection | 3/4″ NPT threaded or cable-suspended |
| Ingress protection | IP68 |
| Cable | 10 m shielded 4-core (20 m / 50 m on request) |
| Warranty | 12 months, Australian-backed |
Typical Australian Applications
- Activated sludge MLSS monitoring in aeration basins
- Secondary clarifier sludge blanket measurement
- Digester feed solids control
- Industrial wastewater suspended solids compliance
- Pulp and paper process water
- Mining tailings and slurry monitoring
- Food & beverage effluent screening
Why Integrators Choose the IDTB-SS-W
- Mechanical wiper eliminates the weekly manual cleaning cycle that every non-wiping probe demands in activated sludge
- Dual-range firmware outputs both turbidity (NTU) and suspended solids (mg/L) on separate Modbus registers
- 30 g/L upper range covers even the heaviest MLSS in digester feeds
- 316 stainless body and sapphire windows survive WWTP chemistries long-term
- Replacement wiper blades and optical window kits stocked locally in Brisbane
Installation & Calibration
Submerge in the aeration basin or install through a 3/4″ NPT pipe boss in a process line. Configure the wiper interval based on fouling observations (start at 15 minutes and adjust). Calibrate both turbidity and SS channels on-site against a grab-sample laboratory TSS analysis. Replacement wiper blades are a 60-second swap without removing the probe from service.
Frequently Asked Questions
How often do I need to replace the wiper blade?
Typically every 6–12 months depending on duty cycle and water abrasiveness. Blade swap is a 60-second on-site procedure.
Can this replace a laboratory TSS analysis?
For process control and trending, yes. For regulatory compliance reporting, calibrate the probe against lab TSS regularly (monthly) and treat the probe as a continuous monitoring instrument backed by lab verification.
Is there a lower-cost version without the wiper?
Yes — see IDTB-IL-316 (Inline Optical Turbidity Sensor) for clean-water applications without fouling.
Will it work in primary sedimentation tanks?
Yes, but at the upper end of the range (10–30 g/L). Position the probe at a stable depth in the sludge layer and configure the wiper to 5-minute intervals during high-flow events.
Australian Technical Support, Calibration & Consumables
- Brisbane-based phone & email technical support from field engineers with 20+ years automation experience
- On-site calibration service across QLD, NSW, VIC with calibration certificate
- Reagents and consumables stocked locally — DPD for free chlorine, formazin for turbidity, all pH and conductivity standards
- Replacement sensors, O-rings, and fittings dispatched same business day ex Brisbane
- Trade pricing for integrators, councils, water utilities, pool & spa contractors
Request a Trade Quote
Panel builders, system integrators, council water departments, water utilities, and food & beverage engineers get volume trade pricing. Submit a quote request and we’ll respond within one business day with stock, pricing, and lead time.

There are no reviews yet.