High-Pressure Alkali pH Electrode – 130°C, 13 bar
The InstroDirect IDH-J605-HP High-Pressure Alkali pH Electrode – 130°C, 13 bar — is a high-pressure, high-temperature alkali-stable pH electrode rated for 13 bar process pressure and 130 °C continuous operation across the full 0–14 pH range. Australian technical support, on-site calibration, open RS485 Modbus compatibility. Alternative to Endress+Hauser and HACH pH sensors.
- Estimated delivery time 3-30 days - some items in stock in Australia
- 12 months standard warranty
- Genuine manufacturer-made products
Product details
High-Pressure Alkali pH Electrode — 13 bar, 130°C, Full 0–14 pH
The InstroDirect IDH-J605-HP High-Pressure Alkali pH Electrode – 130°C, 13 bar is a high-pressure, high-temperature alkali-stable pH electrode rated for 13 bar process pressure and 130 °C continuous operation across the full 0–14 pH range. Designed for demanding high-pressure alkali processes — caustic scrubbing, bauxite refining, pulp & paper kraft process, and high-pressure boiler blowdown.
Technical Specifications
| Parameter | Specification |
|---|---|
| Measuring range | 0 – 14 pH |
| Temperature range | 0 – 130 °C |
| Max Pressure | 13 Bar |
| Bulb Type | High alkali resistant glass |
| Reference type | Open |
| Outer Salt Bridge | Long diffusion path reference |
| Reference solution | High temperature solid polymer |
| Temperature Sensor | PT1000 (S8 interface without temperature sensor) |
| Interface Type | Cab, VP6, S8 |
| Electrode length | 120 mm |
| Mounting Thread | PG13.5 |
Typical Australian Applications
- Bauxite refining (Bayer process)
- Pulp & paper kraft caustic
- High-pressure caustic scrubbing
- Boiler blowdown pH monitoring
- Sodium aluminate processing
- Glass industry silicate process
Why Engineers Choose the IDH-J605-HP
- 13 bar rating is well above standard 6–10 bar electrodes
- Alkali-stable glass resists the “alkaline error” that biases standard electrodes above pH 12
- Pressure-equalised reference prevents pressure-driven electrolyte loss
- Only a handful of suppliers offer this pressure/temperature class in Australia — typical lead times from E+H or HACH are 6–10 weeks
Installation & Calibration
Install via a retractable armature assembly for safe insertion/removal under pressure. Use a pressure-rated process connection (not standard NPT).
Frequently Asked Questions
What is “alkaline error”?
Above pH ~12, sodium ions interfere with the glass bulb electrochemistry, biasing readings low by 0.1–0.5 pH. Alkali-stable glass formulation (used in this electrode) reduces alkaline error to < 0.05 pH even at pH 14.
Australian Technical Support & On-Site Calibration
- Australian field engineers with 20+ years of industrial automation experience — phone and email support during AEST business hours.
- On-site pH calibration service across QLD, NSW, VIC — two-point buffer calibration (pH 4 / 7 / 10) with formal calibration certificate.
- Sensor health diagnostics — slope, offset, glass impedance, and reference junction checks.
- Replacement electrodes and buffer solutions available from InstroDirect’s broader water-analysis range.
Why InstroDirect vs Endress+Hauser or HACH in Australia
InstroDirect supplies the same grade of pH sensor that Australian councils, WWTP integrators, pharma plants, and food & beverage operators specify from Endress+Hauser (CPS11D, CPS31D, CPS41D, CPS71D) and HACH (pHD, Differential pH) — at a significantly lower landed cost and without vendor lock-in.
| Factor | InstroDirect | Endress+Hauser / HACH |
|---|---|---|
| Digital protocol | Open RS485 Modbus RTU — integrates with Allen-Bradley, Siemens, Schneider, Beckhoff, or any SCADA | Proprietary Memosens / HACH SC — locked to the vendor’s transmitter |
| Technical support | Australian field engineers with 20+ years automation experience | Offshore ticket queue or authorised distributor |
| On-site calibration | InstroDirect service across QLD, NSW, VIC with formal certificate | Third-party authorised service network, longer turnaround |
| Price | Parallel-import, no distributor margin stack — typically 30–50% below equivalent E+H / HACH pricing | Premium brand with distributor markup |
| Replacement parts | Standard glass-bulb and reference cartridges | Proprietary Memosens head, tied to the brand |
Moving away from Memosens or SC digital protocols frees you to mix and match sensors with any Modbus-capable transmitter or PLC. InstroDirect pH electrodes drop straight into an existing control system without a new proprietary transmitter.
Request a Trade Quote
Panel builders, integrators, council water departments, and pharma/process teams get volume trade pricing. Submit a quote request and we’ll respond within one business day.
Related products
Stainless 4-Electrode Conductivity SensorRated 0 out of 50 Reviews
The InstroDirect IDC-4E-SS Stainless 4-Electrode Conductivity Sensor — is a heavy-duty four-electrode conductivity probe with a 316 stainless body and slotted protective cage, built for industrial applications that demand both chemical resistance and tolerance to fouling. RS485 Modbus / Pt1000, 0 – 2000 mS/cm, IP68. Backed by Australian technical support, on-site calibration, and next-day Brisbane dispatch.
Residual Chlorine Online AnalyzerRated 0 out of 50 Reviews
Online residual chlorine analyzer by InstroDirect for continuous monitoring of free, combined, or total chlorine in drinking water, WWTP disinfection, cooling water, and pool/spa applications. Choice of DPD colorimetric or amperometric method. 0–5 mg/L or 0–20 mg/L. RS485 Modbus output. AU reagent stock and on-site service.
Free Chlorine Monitoring Panel – Multi-Parameter Wall-Mount SystemRated 0 out of 50 Reviews
Complete multi-parameter free chlorine monitoring panel by InstroDirect — stainless-steel wall-mount assembly with touchscreen controller, transparent flow cell, and pre-wired free chlorine, pH, temperature, and turbidity sensors. Designed for drinking water, pool & spa, cooling tower, and WWTP disinfection monitoring. Fully assembled, calibrated, and ready to drop onto a wall with a single 24V DC feed and a sample line. AU technical support, on-site calibration, and local reagent supply included.
M12 Digital Stainless 2-Electrode Conductivity SensorRated 0 out of 50 Reviews
The InstroDirect IDC-M12-SS M12 Digital Stainless 2-Electrode Conductivity Sensor — is a compact M12-connector digital conductivity probe with a 316 stainless body, designed for plug-and-play installation into modern PLC systems with M12 A-coded I/O. RS485 Modbus / Pt1000, 0 – 20 mS/cm, IP68. Backed by Australian technical support, on-site calibration, and next-day Brisbane dispatch.
COD ID BLACK UV — Reagent-Free Online COD Monitor | UV254 ProbeRated 0 out of 50 Reviews
$0.00
The COD ID BLACK UV is an online, reagent-free COD monitoring probe that uses UV absorption at 254 nm to deliver continuous, real-time measurements of COD, UV254, turbidity, and temperature — with a response time of just 10 seconds. No chemicals. No lab delays. No ongoing consumable costs. Designed for direct immersion in wastewater treatment plants, dairy effluent systems, food processing trade waste, and industrial discharge monitoring applications across Australia.
The COD ID BLACK UV is an online, reagent-free COD monitoring probe that uses UV absorption at 254 nm to deliver continuous, real-time measurements of COD, UV254, turbidity, and temperature — with a response time of just 10 seconds. No chemicals. No lab delays. No ongoing consumable costs. Designed for direct immersion in wastewater treatment plants, dairy effluent systems, food processing trade waste, and industrial discharge monitoring applications across Australia.
Inline Long-Body Stainless 2-Electrode Conductivity SensorRated 0 out of 50 Reviews
The InstroDirect IDC-2W-SS-L Inline Long-Body Stainless 2-Electrode Conductivity Sensor — is an extended-body two-electrode conductivity probe for deep-insertion installations in process tanks, wastewater return lines, and industrial cooling loops. RS485 Modbus / Pt1000, 0 – 200 mS/cm, IP68. Backed by Australian technical support, on-site calibration, and next-day Brisbane dispatch.
The InstroDirect IDC-2W-SS-L Inline Long-Body Stainless 2-Electrode Conductivity Sensor — is an extended-body two-electrode conductivity probe for deep-insertion installations in process tanks, wastewater return lines, and industrial cooling loops. RS485 Modbus / Pt1000, 0 – 200 mS/cm, IP68. Backed by Australian technical support, on-site calibration, and next-day Brisbane dispatch.